BXCWD - X-CON 322 AEROSOL, 5212

  • MSDS: BXCWD
  • Manufacturer: CHEMSEARCH DIV NCH CORP
  • Product Name: X-CON 322 AEROSOL, 5212
  • National Stock Number: 8040-00N058356
Product Identification

Product ID:X-CON 322 AEROSOL, 5212
MSDS Date:12/14/1993
FSC:8040
NIIN:00N058356
MSDS Number: BXCWD

Responsible Party
CHEMSEARCH DIV NCH CORP
IRVING, TX 75015
US

Emergency Phone: 214-438-1381

Info Phone: 214-438-1381

Preparer: R. STOLLEY

Cage: HO026

Contractor
NCH CORP CHEMSEARCH DIV
152170 IRVING, TX 75015 US

Telephone: 972-438-1381/800-527-9919

Cage: 0A782

Ingredients

METHANE, DICHLORO-; (METHYLENE CHLORIDE) (SARA 313)

CAS: 75-09-2

RTECS: PA8050000

OSHA PEL 500 PPM

ACGIH TLV: 50 PPM

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


(ORAL,RAT) 7060 MG/KG.

CAS: 64-17-5

RTECS: KQ6300000

OSHA PEL 1000 PPM

ACGIH TLV: 1000 PPM


PROPANE

CAS: 74-98-6

RTECS: TX2275000

OSHA PEL 1000 PPM

ACGIH TLV: ASPHYXIANT


PROPANE, 2-METHYL-; (ISOBUTANE)

CAS: 75-28-5

RTECS: TZ4300000

OSHA PEL N/K

ACGIH TLV: N/K


0.1%.

CAS: 75-56-9

RTECS: TZ2975000

Fraction By Weight: 0.1%

OSHA PEL 100 PPM

ACGIH TLV: 20 PPM

EPA Report Quantity: 100 LBS

DOT Report Quantity: 100 LBS


GIVE 3-4 GLASSES OF WATER BUT

RTECS: 9999999ZZ


AGAIN. GET IMMED MED ATTN. DO NOT GIVE ANYTHING BY

RTECS: 9999999ZZ


FLAMES OR HOT SURFACES. HEAT &/OR UV RADIATION

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:SEE INGREDIENTS.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:ACUTE:INHAL:MAY CAUSE IRRIT TO RESP
TRACT. MAY CAUSE HDCH, DIZZ, NAUS, LT HEAD, VERTIGO, LOSS OF
APPETITE, DROW/UNCON. EYES/SKIN:MAY CAUSE MOD TO SEV IRRIT.
COMPRESSED LIQ MAY CAUSE FREEZE BURNS. INGE ST:MAY CAUSE IRRIT OF
MOUTH & THROAT, NAUS & NERV SYS EFTS. COMPRESSED LIQ MAY CAUSE
FREEZE BURNS. (EFTS OF OVEREXP)
Explanation of Carcinogenicity:METHYLENE CHLORIDE:IARC MONOGRAPHS SUPP,
VOL 7, PG 194, 1987:GRP 2B. NTP 7TH ANNUAL RPT ON CARCINS,
1994:ANTIC (SUPDAT)
Effects of Overexposure:HLTH HAZ:CHRONIC:RPTD/PRLNG CONT CAN LEAD TO
POSS BURNS TO EYES/SKIN. INHAL OF VERY HIGH CONCS CAN CAUSE DEATH
BY REPLACING OXYGEN. RPTD INGEST CAN CAUSE FETAL ALCOHOL SYNDROME
IN PREGNANT WOMEN. TARG ET ORGANS:LIVER, KIDNEYS, CNS. CHLOROCARBON
MATLS HAVE PRDCD SENSIT OF MYOCARDIUM TO EPINEPHRINE IN LAB ANIMALS
(SUPDAT)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:INHAL:REMOVE TO FRESH AIR. IF NOT BRTHG, CLEAR AIRWAY & START
MOUTH-TO-MOUTH ARTF RESP. GET IMMED MED ATTN. EYE:IMMED RINSE
W/WATER FOR AT LST 15 MINS. HOLD EYELIDS APART TO ENSURE RINSING OF
ENTIRE S URF & LIDS W/WATER. GET IMMED MED ATTN.SKIN:WASH AFFECTED
AREAS THORO W/SOAP & WATER FOR AT LST 15 MINS. REMOVE CONTAM CLTHG
& SHOES. GET IMMED MED ATTN. WASH CLTHG & CLEAN SHOES BEFORE (ING
6)

Fire Fighting

Flash Point Method:SCC
Flash Point:<70F,<21C
Lower Limits:14%
Upper Limits:23%
Extinguishing Media:CO*2, DRY CHEMICAL, WATER SPRAY.
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED PRESSURE DEMAND SCBA &
FULL PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:THERMAL DECOMP PRODUCTS MAY INCLUDE HCL &
PHOSGENE . FORMS FLAMM VAP-AIR MIXTS AT TEMPS ABOVE AMBIENT. LOWER
TEMPS INCR DFCLTY OF GETTING IT TO IGNITE.

Accidental Release

Spill Release Procedures:DUE TO AEROSOL PACKAGING OF THIS PROD, LG
SPILLS ARE UNLIKELY. FOR SM SPILLS, SOAK UP W/INERT MATL & TRANSFER
TO LABELED CNTNRS FOR PROPER DISP. DURING CLEAN-UP WEAR APPROP PROT
CLTHG & ENSURE ADEQUAT E VENTILATION.

Handling

Handling and Storage Precautions:STOR TEMP:MAX:100F; MIN:32F. STORE
INDOORS. AVOID CONT W/SKIN & AVOID BRTHG VAPS. STORE IN COOL, DRY,
WELL-VENTILATED AREA.
Other Precautions:VAPS ARE HVR/AIR & WILL COLLECT IN LOW AREAS. DO NOT
SMOKE IN PRESENCE OF MIST/VAPS. READ ENTIRE LBL BEFORE USING THIS
PROD. KEEP OUT OF REACH OF CHILDREN. NO SMOKING IN AREA OF USE. DO
NOT USE IN GEN VICIN OF ARC WELDING, OPEN (ING 8)

Exposure Controls

Respiratory Protection:IN AREAS OF HIGH CONCENTRATION OR POOR
VENTILATION, WEAR A NIOSH/MSHA APPROVED RESPIRATOR.
Ventilation:USE SUFFICIENT VENT TO MAINTAIN LEVELS BELOW PEL OF
COMPONENTS. MECH VENT MAY BE REQD IN ENCLOSED AREAS.
Protective Gloves:POLYVINYL ALCOHOL GLOVES.
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS .
Other Protective Equipment:EYE WASH FOUNTAIN & DELUGE SHOWER WHICH MEET
ANSI DESIGN CRITERIA .
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
PH:7.5-8.5. EXPLAN OF CARCIN:TO BE CARCIN. ANIMAL:LUNG, LIVER,
SALIVARY, MAMMARY GLAND (TUMORS). EFTS OF OVEREXP:& COULD HAVE
SIMILAR EFT IN HUMANS. ADRENOMIMETICS (E.G., EPINEPHRINE) MAY BE
CONTRAIND ICATED EXCEPT FOR LIFE-SUSTAINING USES IN HUMANS
ACUTELY/CHRONICALLY EXPOS TO CHLOROCARBONS.

Chemical Properties

Boiling Pt:B.P. Text:78.0F,25.6C
Vapor Pres:43 @ 68F
Vapor Density:1.59
Spec Gravity:1.13 (H*2O=1)
pH:SUPDAT
Solubility in Water:NEGLIGIBLE
Appearance and Odor:STRAW COLOR, SLIGHTLY HAZY; METHYLENE CHLORIDE
ODOR.
Percent Volatiles by Volume:63

Stability

Stability Indicator/Materials to Avoid:YES
ALUMINUM, SODIUM, POTASSIUM, MAGNESIUM, AMINES, STRONG OXIDIZERS.
Stability Condition to Avoid:GROSS WATER CONTAMINATION, HEAT, SPARKS &
OPEN FLAME.
Hazardous Decomposition Products:HYDROGEN CHLORIDE, PHOSGENE, ACETIC
ACID & CARBON MONOXIDE, OXIDES OF NITROGEN, AMMONIA, HYDROCHLORIC
ACID.

Disposal

Waste Disposal Methods:DISPOSAL OF I/A/W ALL FEDERAL, STATE & LOCAL
REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.